The HVC80502X X-ray source is an integrated X-ray generator with self-cooling and self-protecting features, with an output of up to 80kV/150W. It is characterized by its compact structure, portable installation, and reliable operation. Within the allowable working temperature range, it can operate continuously at 150W without additional cooling. The HVC80502X X-ray source consists of an X-ray chamber and a control box, and remote control, status monitoring, and firmware upgrades can be achieved via a standard RS232 interface.
Food testing, industrial non-destructive testing, dangerous goods testing and other fields, mostly used for simple X-ray machines or mobile X-ray testing equipment
| Item | Specification | 
| Input voltage | 230VAC±10%, 50/60Hz, 2Amps | 
| Output power of X ray tube | Max continuous output power 150W(30kV/5mA or 80kV/1.8mA ) | 
| Output voltage | Rated output voltage:Continuously adjustable voltage range 20kV—80kV | 
| Output voltage ripple:±0.5%(peak to peak) | |
| Output voltage accuracy:±1% of voltage setting value | |
| line regulation:±0.1% | |
| load regulation:±0.1% | |
| Tube current | Rated tube current:Continuously adjustable current range 0.2mA-5.0mA | 
| Tube current accuracy:±1% mA of current setting value | |
| line regulation:±0.5% | |
| load regulation:±0.5% | |
| Rise time of output voltage | The kV rise time is <0.4 Sec from 10% to 90% of the output voltage. | 
| Filament power supply: | input voltage:24VDC | 
| filament voltage:2.0 to 3.0Vac | |
| filament:3.0 to 3.5 Amps RMS | |
| preheating time:3sec | |
| Tube feature | Tube type:fixed anode、 glass envelope 、tungsten target | 
| focus:0.8mm | |
| inherent filtration:0.8mm Be,0.7mm AI | |
| radiation angle:80º*16º, fan beam | |
| target angle:25° | |
| Cooling | Transformer oil medium, natural heat dissipation | 
| Working temperatures | -10℃—40℃ | 
| Storing temperature | -20℃—60℃ | 
| System temperature protection | 60±3℃ of oil temperature | 
| Humidness | 98%,Non-condensation | 
| Weight | 23kg | 
| Installation direction | Installation in any direction | 
| Radiation angle | 16°×80° | 
| X-ray leakage | Less than 0.5mR/hr at 5cm from the surface of the HVC80502 Integrated X-Ray Source. | 
JB1/AC~(AC Input Power Connector)
| Pin | Signal | Parameter | 
| 1 | L | live wire | 
| 2 | N | Neutral line | 
| 3 | G | PE | 
JB2/COM (DMR-9S interface definitions)
| Pin | Signal | Parameter | 
| 1.4.6.7.8.9 | N/C | No connect | 
| 2 | TXD | Data transmit | 
| 3 | RXD | Data receive | 
| 5 | GND | Signal gnd | 
JB3/Interlock,(DMR-9P interface definitions)
| Pin | Signal | Parameter | 
| 3/4/5/6/7/8/9 | N/C | No connect | 
| 1 | Interlock Out | |
| 2 | Interlock In | 
Short connect pin1 and pin2 make X ray source normal operation. Typical connection:
Led indicator:
| ID | Color | Meaning | 
| XrayOn | Yellow | indicate X ray on | 
| ARC | Red | Arcing in oil tank | 
| OT | Red | Over temperature | 
| EP_Err | Red | Tube voltage error | 
| IP_Err | Red | Tube current error | 
| Power | Green | Power on | 
Tank size
Copyright@2024, All Rights Reserved